Style Number: | UL10369 | Insulation Material: | XLPE |
Rated Temperature: | 105 deg C | Rated Voltage: | 600V |
Average Insulation Thickness: | 20 mils | Minimum Insulation Thickness: | 18 mils |
UL10369 XLPE Wire
Conductor Size: 30AWG - 9AWG.
Conductor Material: Annealed bare or tinned, stranded or solid copper conductor.
Insulation Material: Crosslinked Polyethylene XLPE.
Wire Colour: optional colour schemes such as black, brown, red, orange, yellow, green, blue, violet, grey, white, pink, etc.
UL VW-1 and CSA FT1, FT2 flammability test verified, RoHS compliant.
Application: Internal wiring of appliances.
Standard: UL758, UL1581, CSA22.2.
Uniform insulation thickness for easy stripping process.
Origin: Dongguan, China.
Style Number | Conductor | Insulation Thickness | Overall Diameter | Standard Packing Quantity | Conductor Resistance |
AWG | No/mm | mm | mm | Feet/reel | Meter/reel | Ω/KM |
UL10369 | 30 | 7/0.10 | 0.51 | 1.35 | 2000 | 610 | 150.00 |
28 | 7/0.127 | 0.51 | 1.45 | 2000 | 610 | 94.20 |
26 | 7/0.16 | 0.51 | 1.60 | 2000 | 610 | 150.00 |
24 | 11/0.16 | 0.51 | 1.70 | 2000 | 610 | 94.20 |
22 | 17/0.16 | 0.51 | 1.85 | 2000 | 610 | 59.40 |
20 | 21/0.178 | 0.51 | 2.05 | 2000 | 610 | 36.70 |
18 | 34/0.178 | 0.51 | 2.30 | 2000 | 610 | 23.20 |
16 | 26/0.25 | 0.51 | 2.60 | 2000 | 610 | 14.60 |
14 | 41/0.25 | 0.51 | 3.00 | 1000 | 305 | 8.96 |
12 | 65/0.25 | 0.51 | 3.50 | 1000 | 305 | 5.64 |
10 | 105/0.25 | 0.51 | 4.10 | 1000 | 305 | 3.55 |