Style Number: | UL1431 | Insulation Material: | XL-PVC |
Rated Temperature: | 105 deg C | Rated Voltage: | 600V |
Average Insulation Thickness: | 30 mils | Minimum Insulation Thickness: | 27 mils |
UL1431 XL-PVC Wire
Conductor Size: 30AWG minimum.
Conductor Material: Annealed bare or tinned, stranded or solid copper conductor.
Insulation Material: Irradiation cross-linked PVC.
Wire Colour: optional colour schemes such as black, brown, red, orange, yellow, green, blue, violet, grey, white, pink, etc.
UL VW-1 and Cul FT1, FT2 flammability test verified, RoHS compliant.
Application: Internal wiring of appliances, motor leads.
Standard: UL758, UL1581.
Uniform insulation thickness for easy stripping process.
Approval Marking: UL, Cul.
Origin: Dongguan, China.
Style Number | Conductor | Insulation Thickness | Overall Diameter | Standard Packing Quantity | Conductor Resistance |
AWG | No/mm | mm | mm | Feet/reel | Meter/reel | Ω/KM |
UL1431 - TS | 26 | 7/0.16 | 0.76 | 2.10 | 2000 | 610 | 150.00 |
24 | 11/0.16 | 0.76 | 2.20 | 2000 | 610 | 94.20 |
22 | 17/0.16 | 0.76 | 2.40 | 2000 | 610 | 59.40 |
20 | 21/0.178 | 0.76 | 2.60 | 2000 | 610 | 36.70 |
18 | 34/0.178 | 0.76 | 2.80 | 2000 | 610 | 23.20 |
16 | 26/0.25 | 0.76 | 3.10 | 1000 | 305 | 14.60 |
14 | 41/0.25 | 0.76 | 3.50 | 1000 | 305 | 8.96 |
12 | 65/0.25 | 0.76 | 4.10 | 1000 | 305 | 5.64 |
10 | 105/0.25 | 0.76 | 5.10 | 1000 | 305 | 3.55 |
UL1431 - TC | 26 | 7/0.16 | 0.76 | 2.10 | 2000 | 610 | 140.00 |
24 | 7/0.20 | 0.76 | 2.20 | 2000 | 610 | 88.70 |
22 | 7/0.25 | 0.76 | 2.40 | 2000 | 610 | 54.70 |
20 | 7/0.32 | 0.76 | 2.60 | 2000 | 610 | 37.10 |
18 | 7/0.40 | 0.76 | 2.80 | 2000 | 610 | 23.70 |
UL1429 - Solid | 26 | 1/0.404 | 0.76 | 2.00 | 2000 | 610 | 143.00 |
24 | 1/0.511 | 0.76 | 2.15 | 2000 | 610 | 89.30 |
22 | 1/0.634 | 0.76 | 2.30 | 2000 | 610 | 56.40 |
20 | 1/0.813 | 0.76 | 2.45 | 2000 | 610 | 35.20 |
18 | 1/1.024 | 0.76 | 2.75 | 2000 | 610 | 22.20 |